Hélicoptères Guimbal
SECTION 7
CABRI G2
SYSTEMS DESCRIPTIONS
7-10
Approved under DOA EASA.21J.211
Battery breakers
Four breakers are located in the battery shelter, two of which are in
direct battery :
Note
:
They are “push” breakers except for the Auxiliaries one (refer to
Instrument panel and console
The standard flight instruments include airspeed indicator, altimeter,
vertical speed indicator, magnetic compass and the EPM.
Space is available for one additional conventional instrument.
Refer to Night VFR supplement (Section 9) for wide instrument panel.
The basic avionics stack includes a VHF transceiver, transponder and
an intercom.
Space is available for additional equipment.
Emergency locating transmitter
The ELT is located inside the luggage compartment. It is attached to the
main bulkhead by a strap in the lower corner.
The ELT switch should be in ARMED position. Then the 3-position
switch on the breaker panel can be used for remote control :
•
ON (transmission) enables manual activation of the ELT,
•
ARMED : stand by mode to enable automatic activation by the
shock sensor. Unless there is an emergency, the switch must
stay in that position.
For additional features, refer to ELT operation manual.
5
A
5
A
5
A
Voltage regulator
BARC backup
power supply
Auxiliaries
Voltage reference for alternator regulator
Master relay
- Remote door locking,
-
“Magneto disabling during
cranking” function
- 13.7 V Aux. socket
(direct battery)
BARC backup
5
A
(direct battery)