
70
Expert Power Control 1202/1292
© 2018 Gude Analog- und Digitalsysteme GmbH
Specifications
ethernet
enters cmd group "ethernet"
ethernet mac show
shows MAC address
ethernet link show
shows ethernet link state
ethernet phyprefer set {10MBIT_HD=0|
10MBIT_FD=1|100MBIT_HD=2|100MBIT_FD=3}
sets preferred speed for PHY Auto Negotiation
ethernet phyprefer show
shows preferred speed for PHY Auto Negotiation
extsensor
enters cmd group "extsensor"
extsensor {port_num} {sen_field} value show
shows sensor value
6
extsensor {port_num} {sen_type} label set
"{name}"
sets sensor name to label
6
extsensor {port_num} {sen_type} label show
shows label of sensor
6
extsensor {port_num} type show
shows type of sensor
extsensor {port_num} {sen_type} {sen_field}
events set {off=0|on=1}
enables sensor events on/off
6
extsensor {port_num} {sen_type} {sen_field}
events show
shows if sensor events are enabled
6
extsensor {port_num} {sen_type} {sen_field}
events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2
,EVT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER
=5}"
enables different event types
6
extsensor {port_num} {sen_type} {sen_field}
events type show
shows what event types are enabled
6
extsensor {port_num} {sen_type} {sen_field}
maxval set {num}
sets maximum value for sensor
6
extsensor {port_num} {sen_type} {sen_field}
maxval show
shows maximum value for sensor
6
extsensor {port_num} {sen_type} {sen_field} min-
val set {num}
sets minimum value for sensor
6
extsensor {port_num} {sen_type} {sen_field} min-
val show
shows minimum value for sensor
6
extsensor {port_num} {sen_type} {sen_field} hyst
set {num}
sets hysterese value for sensor
6
extsensor {port_num} {sen_type} {sen_field} hyst
show
shows hysterese value for sensor
6
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num}
sets Port for Power Port Switching actions
6
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
shows Port for Power Port Switching actions
6
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
sets Port state for Power Port Switching actions
6
extsensor {port_num} {sen_type} {sen_field}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
shows Port state for Power Port Switching actions
6
extsensor period set {24H=0|12H=1|2H=2|1H=3|
30MIN=4}
sets sensor Min/Max measurement period
extsensor period show
shows sensor Min/Max measurement period
http
enters cmd group "http"
http server set {HTTP_BOTH=0|HTTPS_ONLY=1|
HTTP_ONLY=2}
sets connection types the webserver accepts
http server show
shows webserver accepting connection types
http port set {ip_port}
sets http port
http port show
shows http port
http portssl set {ip_port}
sets https port
http portssl show
shows https port
http ajax enabled set {OFF=0|ON=1}
enables ajax autorefresh on/off
http ajax enabled show
shows if ajax autorefresh enabled
http passwd enabled set {OFF=0|ON=1}
enables http password on/off
http passwd enabled show
shows if http password enabled
http passwd user set "{passwd}"
sets http user password
http passwd admin set "{passwd}"
sets http admin password
http passwd hash user set "{passwd}"
sets hashed http user password
http passwd hash admin set "{passwd}"
sets hashed http admin password
ip4
enters cmd group "ip4"
ip4 hostname set "{name}"
sets device hostname
ip4 hostname show
shows device hostname
3
ip4 address set "{ip_address}"
sets IPv4 address
ip4 address show
shows IPv4 address
3
ip4 netmask set "{ip_address}"
sets IPv4 netmask
ip4 netmask show
shows IPv4 netmask
3
Summary of Contents for Expert Power Control 1202
Page 2: ...2 Expert Power Control 1202 1292 2018 Gude Analog und Digitalsysteme GmbH...
Page 6: ...Device Description...
Page 14: ...Operating...
Page 36: ...Configuration...
Page 56: ...Specifications...
Page 88: ...Support...