Geophysical Survey Systems, Inc.
PaveScan® RDM 2.0
Manual
MN36-716 Rev A
16
11
After pressing
the File Information screen opens. There are several user entries tied to each
file.
File Information Screen
Collect Mode:
Select the collection mode.
•
Distance Mode – collects measurements at specified distance intervals as the sensors are moved.
The distance intervals are determined by the collect option selected in System Settings (see
section 2.3).
•
Time Mode - collects a continuous file at a rate of 60 measurements per second. This mode is
often used when making a static (non-moving) measurement at a specific location.
•
Core Mode - starts data collection of a 4 ft (1.2 m) file using a survey wheel. Position the sensor
about 2 ft (0.6 m) from the core location, press start, then move the sensor over the core. When
the sensor is over the core location, press the
Add Mark
button to indicate the exact location of
the core in the data file.
Starting Station Number:
This is that starting station number of the file. If stationing is disabled
(accessed by
Project Info
button), this entry will not appear. When the Auto Start Distance Project option
is selected (accessed by
Project Info
button), this value is automatically specified based on the ending
distance of the previously-collected file.
Starting Station Distance (ft/m):
This is shown when stationing is being used. It’s a value ranging
from 0-99.9. When the Auto Start Distance Project option is selected (accessed by
Project Info
button),
this value is automatically specified based on the ending distance of the previously-collected file.
Starting Distance (ft/m):
This value, shown when stationing is not being used, is the distance used as
the starting distance in the output file containing dielectrics and % voids. When the Auto Start Distance
Project option is selected (accessed by
Project Info
button), this value is automatically specified based on
the ending distance of the previously-collected file.
Summary of Contents for PaveScan RDM 2.0
Page 1: ...MN36 716 Rev A ...
Page 4: ...Geophysical Survey Systems Inc PaveScan RDM 2 0 Manual MN36 716 Rev A ...
Page 6: ...Geophysical Survey Systems Inc PaveScan 2 0 RDM Manual ...
Page 8: ...Geophysical Survey Systems Inc PaveScan RDM 2 0 Manual MN36 716 Rev A 2 ...
Page 34: ...Geophysical Survey Systems Inc PaveScan RDM 2 0 Manual MN36 716 Rev A 28 ...
Page 46: ...Geophysical Survey Systems Inc PaveScan RDM 2 0 Manual MN36 716 Rev A 40 ...
Page 50: ...Geophysical Survey Systems Inc PaveScan RDM 2 0 Manual MN36 716 Rev A 44 ...
Page 52: ...Geophysical Survey Systems Inc PaveScan RDM 2 0 Manual MN36 716 Rev A 46 ...
Page 64: ...Geophysical Survey Systems Inc PaveScan RDM 2 0 Manual MN36 716 Rev A 58 ...
Page 66: ...Geophysical Survey Systems Inc PaveScan RDM 2 0 Manual MN36 716 Rev A 60 ...
Page 67: ......