5. Installation
PNEG-1162CEX
DMC DIII Stir-Ator
33
9. Re-check and adjust as required so that the tilt switch opens at the required distance.
10. When adjustment is complete, shut the power OFF; remove the test light or voltmeter; reconnect the
track motor cable; and re-set the auger motor overloads.
Figure 5BA Auger Trail-Back Distance
Auger Length
Auger Trail-Back Distance
6.5 m
1000 mm
5.5 m
870 mm
4.5 m
710 mm