Cable C: Input for dosing stop and dosing monitoring or dosing output
Number / colour
1 / brown
2 / white
3 / blue
4 / black
5 / grey
Function
Dosing stop (input)
5 V
Ground
Dosing stop (input)
Potential-free
Potential-free
Dosing monitoring
Potential-free
Potential-free
Dosing monitoring
Ground
5 V
Dosing output (pump
running)
Open collector
(NPN)
Ground
2)
Open collector (NPN) can be used for a relay or a lamp.
1. Using the internal 5 VDC power supply:
Max. current: 100 mA
2. Using an external power supply:
Max. 24 VDC - 100 mA
1
3
5
2
4
C
A
B
TM037868
1
3
5
2
4
A
TM037869
Pos.
Description
A
Lamp
B
Power
C
Relay