4
TM077987
Pos. Description
1
Total dosed quantity
2
Total number of strokes
3
Total number of operating hours
4
Total number of starts
5
Operating display
5.18 Resetting
When "DEFAULT" is activated, the pump will return to
the factory settings.
Note:
The calibration is also set back to the default
setting. This means that a new calibration is required
when the "DEFAULT" function has been used.
Default settings are the factory settings of standard
pumps. Select "DEFAULT" in the "SETUP" menu.
Default settings:
Operating mode:
Manual
Capacity:
Maximum capacity
Control panel lock: Unlocked
Default lock code:
2583
Anti-cavitation:
Not active
Analog signal:
4-20 mA
Digital inputs:
NO (normally open)
Capacity limitation: Maximum capacity
Alarm reset required to restart the pump
Dosing monitoring: Off
Language:
English
Units:
Metric