5. Functions
5.1 Control panel
100%
1
2
3
4
5
6
7
8
9
10
11
12
13
14
TM027068
Pos. Description
1
LCD display.
See section Menu
2
Navigation/settings.
See section Menu
3
Green indicator light.
See section Alarm output and indicator lights
4
Maximum capacity (priming).
See section Priming/venting of pump
5
Red indicator light.
See section Alarm output and indicator lights
6
M12 connection analog/pulse/leakage input.
See sections Pulse, Analog, Diaphragm
leakage sensor
7
Cable for Profibus control.
See section Fieldbus communication
8
Connection alarm relay.
See section Alarm output and indicator lights
9
Power supply
10
M12 connection level control.
See section Level control
Pos. Description
11
M12 connection stop dosing.
See section Start/stop of pump
12
On/off button.
See section Menu
13
Navigation/settings.
See section Menu
14
Menu.
See section Menu
Related information
5.2 Start/stop of pump
5.3 Priming/venting of pump
5.4 Level control
5.5 Diaphragm leakage sensor
5.7 Fieldbus communication
5.8 Menu
5.11 Pulse
5.12 Analog
5.2 Start/stop of pump
The pump can be started/stopped in two different
ways:
•
Locally on the pump control panel.
•
By means of an external on/off switch. See
section Connection overview.
Related information
5.3 Priming/venting of pump
The pump control panel incorporates a
100%
button.
Press this button if the maximum pump capacity is
required over a short period, e.g. during start-up.
When the button is released, the pump automatically
returns to the previous operating mode.
During priming/venting, it is recommended to let the
pump run without a counter pressure or to open the
vent valve.
Note:
When the buttons
100%
and
are pressed
simultaneously, the pump can be set to run for a
specific number of seconds at maximum capacity.
The remaining number of seconds will appear in the
display. The maximum value is 300 seconds.
17
English (GB)
Summary of Contents for DME 150 AP
Page 2: ......