Example:
If the calibration factor is 625 (= 6.25 ml/stroke), the
minimum settable value in timer or batch mode will be
6.25 ml (= 1 stroke) -> the next will be 12.5 ml
(= 2 strokes), etc.
These steps will continue up to a value corresponding
to 100 dosing strokes. Above this value, the setting
range has standard steps as in other operating
modes.
If the calibration factor is changed after the setting of
timer or batch mode, the pump will automatically
recalculate a new number of dosing strokes per batch
and change the display value to the nearest possible
value compared to the first one set.
1
2
3
4
5
6
7
TM077997
Pos. Description
1
Set quantity per batch
2
Set IN value in days
3
Set IN value in hours
4
Set IN value in minutes
5
Set NX value in days
6
Set NX value in hours
7
Set NX value in minutes
23