4
3. Product description
As standard, Hydro MPC booster sets consist of two to six pumps
coupled in parallel and mounted on a common base frame with all
the necessary fittings and a control cabinet.
Fig. 1
Hydro MPC booster set
Hydro MPC booster sets are divided into seven groups based on
control type:
See also
6.1 Examples of control variants
.
Hydro MPC booster sets always includes application-optimised
software for setting the booster set to the application in question.
Note
A diaphragm tank must be included in most
installations.
TM0
3
1
1
71
12
05
Pos.
Description
Quantity
1
Control cabinet
1
2
Nameplate
1
3
Suction manifold (stainless steel)
1
4
Isolating valve
2 per pump
5
Base frame (stainless steel)
1
6
Non-return valve
1 per pump
7
Discharge manifold (stainless steel)
1
8
Pressure transmitter/pressure gauge
on suction and discharge manifolds
2
9
Pump
2 - 6
1
2
3
4
5
6
7
8
9
Control
variant
Description
-E
2 to 6 CRE pumps
-ED
2 CRE pumps and up to 4 mains-operated CR pumps
-ES
1 CRE pump and up to 5 mains-operated CR pumps
-EF
2 to 6 CR pumps connected to external frequency
converters
-EDF
2 CR pumps connected to external frequency
converters and up to 4 mains-operated CR pumps
-F
Up to 6 CR pumps connected to an external frequency
converter. The speed controlled operation alternates
between the pumps.
-S
2 or 6 mains-operated CR pumps
www.motralec.com / [email protected] / 01.39.97.65.10