20
10.4.5 Setpoint influence (1.2.3)
Fig. 13
Setpoint influence
Description
The selected setpoint can be influenced by parameters. The
parameters, shown as percentage from 0 to 100%, can only
reduce the setpoint, as the influence is multiplied with the
selected setpoint:
The display shows the parameters influencing the selected
setpoint and the percentage of influence.
Finally the resulting current setpoint is shown.
10.4.6 Measured values (1.2.4)
Fig. 14
Measured values
Description
This display gives a general status of all measured and calculated
parameters.
10.4.7 Pump status (1.3 to 1.8)
Fig. 15
Pump status
Description
This display shows the operational state of the individual pumps.
The pumps may have different operating modes:
•
Auto
Together with the other pumps in automatic operation the
pump is controlled by the PI controller which ensures that the
booster set delivers the required performance (pressure).
•
Manual
The pump is not controlled by the PI controller. In manual
operation, the pump has one of the following operating modes:
-
Max.
The pump runs at a set maximum speed.
-
Normal
The pump runs at a set speed. (This operating mode can
only be selected for variable-speed pumps.)
-
Min.
The pump runs at a set minimum speed. (This operating
mode can only be selected for variable-speed pumps.)
-
Stop
The pump has been forced to stop.
Besides information about the operating mode, it is possible to
read various parameters in the status display, such as:
•
speed (only 0 or 100% are shown for mains-operated pumps)
•
power consumption (only CR(I)E pumps)
•
energy consumption (only CR(I)E pumps)
•
operating hours.
10.5 Operation
In this menu, the most basic parameters can be set, such as
setpoint, operating mode, control mode and forced control of
pumps.
T
M
03
22
71
40
05
TM
03
22
70
40
05
Note
The lines Power consumption and Energy
consumption are only shown in Hydro MPC-E
booster sets.
Setpoint
Current
Setpoint
Select
.
Influence(1)
×
Influence(2)
…
×
×
=
T
M
03
22
68
40
05