Appendix A
A.1. Wiring diagrams
Equipment
-X1
U
1
2
3
V
W
U
V
W
T1
T3
T1
4
5
6
7
T3
S1
S1
S2
S2
PE
customer
supplied
power cable
star connection
temperature
seal probe
oil chamber
electrodes
temperature switch
SUBMERSIBLE PUMP
monitoring
winding
motor winding
10
U1
V1
W1
U2
V2
W2
T1
T3
sw
bl
th-controller
S1
S2
Wiring diagram
WARNING
Electric shock
Death or serious personal injury
‐
Make sure the earth and phase conductors are not mixed up, and the earth conductor is
connected first.
427