Water Softener
WINNI-mat
®
VGX
Order no. 215 188 040-inter Edited by: KONS-pha-rg G:\BA-188040-INTER-VGX.DOC
13
Table C-1: Technical specifications
Water Softener WINNI-mat
®
VGX
9
14
19
14
H
Connection data
Connection diameter
DN 25 (1" AG)
Drain connection min.
DN 50
Power supply
[V]/[Hz]
230/50-60
(system operation with protective low voltage 24/50-60)
Connected load
Operation = max. / standby
[VA]
17 / 13
Protection/protection class
IP 54/I
Performance data
Nominal pressure
PN 10
Operating pressure min/max. (recommended) [bar]
2.0/8.0
(4.0)
Nominal flow at 0.8 bar pressure loss (raw
water 20 °dH (35.6 °f, 3.56 mmol/l) and soft
water hardness 8 °dH (14,2 °f, 1,42 mmol/l))
[m³/h]
1.7
2.1
2.1 -
Nominal flow at 0 °dH (0 °f, 0 mmol/l) [m³/h]
1.3
1.4
1.4 0.5
Nominal flow acc. to DIN EN 14743
(pressure loss 1 bar
≙
K
V
value)
[m³/h]
1.6
1.7
1.7 -
Nominal capacity [mol]
1.6
2.4
3.2
2.4
Capacity per kg of regeneration salt
[mol/kg]
4.5
4.5
4.3 2.9
Duration of regeneration [min]
50
60
70
68
Dimensions and weights
1)
A System width
[mm]
330
B System height [mm]
640
C System depth
[mm]
530
D Height of safety overflow brine tank
[mm]
395
E Connection
height of control valve
[mm]
507
F Installation length without
screw connection
[mm]
190
-
G Installation length
with screw connection
[mm]
271
-
Operating weight, approx.
[kg]
60
73
75 73
Weight empty, approx.
[kg]
25
28
30 28
Filling volumes and consumption data
Resin filling volume
[l]
4
6
7.5
6
Salt consumption per regeneration approx.
*
[g]
350
530
750 850
Regeneration salt supply max.
[kg]
38
Total waste water volume per regeneration, approx.
[l]
30
40
50
53
General information
Suitable for homes of … families (up to … persons)
2)
1-2 (5)
3-5 (12)
6-8(20)
-
DVGW registration number
NW-9151BP5635
SVGW certificate number
test pending
Max. water/ambient temperature
3)
[°C]
30/40
Order no.
188 100
188 200
188 300
188 250
*
The waste water volume and salt consumption refer
to an inlet pressure of 3 bar. The indicated values
change at different inlet pressures and only serve as
a means for a rough analysis.
1)
All indications are approximate.
2)
Recommendation for installation in Switzerland: VGX
9 for one-family homes, VGX 14 for 2-family homes,
VGX 19 for 3-family homes
3)
Refer to installation requirements!
Fig. C-1: Dimensional drawing
WINNI-mat
®
VGX