Water Softener
WINNI-mat
®
VGX
Order no. 215 188 040-inter Edited by: KONS-pha-rg G:\BA-188040-INTER-VGX.DOC
33
2 | Operation of control system
2.1 Operating Panel and Display
1 „Program“ key
in standard operation:
switches to programming level (hold down
for more than 1 s).
on programming level:
opens menus.
stores the settings and closes menus.
2 „Hand Reg“ key
in standard operation:
releases manual regeneration
(hold down for more than 10 s).
on programming level:
switches to previous menu
decreases numerical values.
3 „Info“ key
in standard operation:
activates the info level and switches to the
next screen
Fig. F-2: Control system, operating panel and display
on programming level:
switches to the next menu
increases the numerical values.
4 Display
indicates the operating parameters
(refer to 5 - 10).
5 „Einheit/Unit“ indication
indicates the unit of the adjacent numeri-
cal value (e.g. °dH, °f, mol, m
3
....).
6 „Regeneration“ indication
indicates the regeneration progress. Each
arrow represents one step in the regen-
eration. When the arrows form a circle,
the regeneration is completed.
7 „Exchanger “ indication
indicates the operating status of the ex-
changer.
8 „Water flow pulses“ indication
indicates the water flow.
9 „Numerical values“ indication
indicates the time in the basic mode. When
the activated service/maintenance interval
has expired, the signal SEr is indicated.
indicates the operating parameters on the
info level.
indicates the values in the menu on the pro-
gramming level. Open menus are blinking.
10 „Chlorine arrow“ indication
indicates the electric current during the re-
generation step “salting” by means of the dis-
infection cell.