Water softener
GENO-mat duo WE-X,
GENO-mat duo WE-OSMO-X
Order no. 074 184 046-inter Edited by: phar/mrie G:\BA-184046-inter_074_GENO-mat duo_WE-X.docx
23
1.2.2 Connections to external or optional components
From IONO-matic
WE control unit
to component
Line
Signal
15
Programmable input
+ 24 V=
16
IN
17
Option pre-alarm
salt supply 185335
LiYY 4x0.25 mm²
+ 24 V=
BN
18
IN
BK
19
GND
BU
29
Collective fault
Max. 250 V~ /
max. 3 A each
30
Common root
31
Signal contact
1.2.3 Connections to networked GENO-OSMO-X reverse osmosis
From IONO-matic
WE control unit
to component
Line
Signal
38
Bus line to
OSMO-X
control unit
93
LiYY 3x0.25 mm²
(*)
RS485 A
39
94
RS485 B
GND2
95
RS485-GND
(*) With cable length > 20 m: Use LiYcY 3x0.25 mm² and
connect the shielding at one end either in the OSMO-X control
unit or IONO-matic WE/control unit DEA at a free PE terminal.
2 | Preliminary work
1. Unpack all system components.
2. Check for completeness and soundness.
3. Set up both exchanger tanks at the intended site.
Caution!
The system only functions if it is set up correctly. Set
up the exchanger tank with control valve on the right (seen from
the front).
Only with small systems (nominal connection diameter 1"):
The connection hoses with pre-installed connection adapters
and coupling pieces are exposed.
4. Plug in coupling pieces.
5. Install hoses between control valve and bottle adapter.
6. Fit connection block for raw water connection.
Note:
The connection block is supplied with separate installation
instructions.
Summary of Contents for GENO-mat duo WE-OSMO-X 130
Page 2: ......