Water softener
GENO-mat duo WE-X,
GENO-mat duo WE-OSMO-X
Order no. 074 184 046-inter Edited by: phar/mrie G:\BA-184046-inter_074_GENO-mat duo_WE-X.docx
35
2.4 System status display
The residual capacity of the exchanger bottle in operation is
displayed in %.
For the exchanger bottle that is undergoing regeneration, the
current flow direction is indicated by arrow symbols.
In addition to the water meter symbol, the 0 °dH flow rate
currently coming from the system is displayed in m³/h.
If the pre-alarm salt supply (Order no.185335) option is fitted,
the brine tank is shown as empty when salt tablets need to be
refilled.
2.5 Setting operating
parameters – operator
menu
On start-up, at least the time and raw water hardness must be
programmed (see table below, printed in bold). The raw water
hardness must be set to the highest hardness that is
encountered, if there are fluctuations in the water quality.
Starting point: Basic display (time/residual capacity/time since
last regeneration)
Press and hold P key for > 1 sec. >>
Operator menu appears.
Parameters
Factory setting
Setting range
Comment
Raw water
hardness
[°dH] 25
1…250
Data logging (*)
No
No/Yes
On internal SD-card (*),
Card slot for SD-card on
operating board
Interval
[Min] 60
1…999
Time
XX:XX
00:00…23:59
Date
XX.XX.XX
(*) The Yes setting means the following information is recorded in the set interval:
Residual capacity of the exchanger in operation
(C XX.XX m³).
Current flow (Q XX.XX m³/h).
Time since last regeneration (T XXX h).
Current regeneration step
0 = No regeneration
1 = Backwashing
2 = Salting
3 = Slow rinsing
4 = Washing out
5 = Filling brine tank
Time until service is due (S XXX d).
Regeneration counter (XXXXXX).
Soft water meter (XXXXXX m³).