Water softener
GENO-mat duo WE-X,
GENO-mat duo WE-OSMO-X
Order no. 074 184 046-inter Edited by: phar/mrie G:\BA-184046-inter_074_GENO-mat duo_WE-X.docx
22
1.2.1 Connections to other subsystems within the water softener
The following connections are preset internally at the factory and
must not be modified (cables to be connected by the client are
marked with *).
Table D-1:
From IONO-matic
WE control unit
to component
Line
Signal
1
Mains cable
H05VV-F 3G0.75
mm²
L
BN
2
N
BU
PE
Earth wire
YE-GN
3
Reserved terminals
4
5
6
PE
7
8
PE
9
10
PE
11
Microswitch
control valve* (3
terminals on the right
on the terminal strip
at the control valve
LiYY 3x0.5 mm²
+ 24 V=
Litz wire 1 BK
12
S1
Litz wire 2 YE
13
+ 24 V=
14
S2
Litz wire 3 OG
Colour of litz wire
Line
Motor
20
Step motor control
valve* (3 terminals
on the left)
LiYY 7x0.25 mm²
+ 24 V=
GN
BU
21
Ph1
BN
YE-BK
22
Ph2
GY
BK
23
(3 terminals in the
middle at the control
valve)
+ 24 V=
WH
BU
24
Ph3
YE
YE
25
Ph4
RS
RD
26
Water meter*
LiYY 3x0.25 mm²
+ 12 V=
WH
27
pulse
GN
28
GND
BN
32
Pot.-free contact, closed when
exchanger tank 1 in operation.
Switching capacity
max. 30 V~1A
33
34
Pot.-free contact, closed during
regeneration.
35
GND1
Connection to the
programming board
LiYY 5x0.34 mm²
GND-RS WH
40
RS485B
GY
41
RS485A
GN
GND
GND
YE
42
+ 14 V=
BN