Water softener
GENO-mat duo WE-X,
GENO-mat duo WE-OSMO-X
Order no. 074 184 046-inter Edited by: phar/mrie G:\BA-184046-inter_074_GENO-mat duo_WE-X.docx
31
Setting the blending unit
In the GENO-mat duo WE-X 50, duo WE-X 130 and duo
WE-X 230 systems, the blending unit described here is mounted
on the control valve. Optionally, small systems with full salting
can be equipped with it. In all other cases, the operating manual
for the installed blending valve applies.
1. Open the valve on the raw water inlet.
2. Open the valve on the soft water outlet.
3. Set the adjusting cap (1) to a mean scale value.
4. Take a water sample at the sampling valve downstream of
the system.
5. Perform a hardness test using the "Total hardness" water
inspection device.
6. Set the blending hardness as required.
In order to do so:
Turn the adjusting cap to the left (close) so as to reduce
the blending hardness.
Turn the adjusting cap to the right (open) so as to increase
the blending hardness.
7. Repeat steps 4. and 5. until the desired blending hardness is
reached.
2.2 How to set the control
unit
The GENO-mat duo WE-X water softener is volume-controlled.
The operating parameters are already stored in the GENO-
IONO-matic WE-X control unit. During start-up, all parameters
must be entered which are required for the automatic calculation
of the regeneration interval.
Note:
For detailed information on the handling of the
GENO-IONO-matic WE-X control unit, please refer to chapter F.
2.2.1 Setting the time and
raw water hardness
Starting from the basic display
Press and hold key P for > 1 second. The parameters can be
accessed there.