40
1
4
3
2
7.
Input and output signals - time control
LUB-V can be switched off completely by switching off the supply voltage. Its settings will
not be lost: the integrated microelectronics automatically store the remaining time until
the next scheduled lubrication cycle. After reapplying the supply voltage LUB-V automati-
cally checks itself and continues to operate according to the set values.
After a long standstill of LUB-V a "quick check" is recommended (chapter 6.3.6).
The output signal at PIN 4 can be tapped for further processing (e.g. indicator light or
external control). The maximum permissible current output must not exceed I
max
< 20mA.
No inductive load (e.g. relay) may be connected!
PIN assignment
PIN
Assignment
Colour
1
+24 V DC
brown
2
unallocated
white
3
ground
blue
4
output signal
black
Type: M12x1 female connector; 4-pin, A-coded
LCD
Description
Output Signal (PIN 4)
Chapter
OFF
switched off
low, permanent
7.3
On
ready for operation
high, permanent
E1
cartridge empty
0,5Hz square wave signal,
permanent
E2
overload
low, permanent
E3
undervoltage
low, permanent
E4
fatal error
low, permanent
7.1
Pin assignment - time control
LUB-V operates in hour mode -h- as a time-based and cycle-controlled lubrication system
according to the values set in PRO menu.
7.2
Output signals and LCD messages - time control