25
Display in LCD Meaning
Chapter
no display
Power supply not connected
5.3
OFF
LUB-V is switched off
6.3.3
On
LUB-V is ready for operation; LUB-V dispenses lubricant
in accordance to the operating mode and the values set
6.3.3
PUL
LUB-V is ready for operation in impulse mode PUL and
waits for control signals from the PLC
8
PUL (flashing)
LUB-V is receiving a control signal from the PLC
8
---
Received control signal longer than 15 seconds
8.2
Errors
E1
Error E1 (empty cartridge)
6.4
E2
Error E2 (overload / overpressure)
6.4
E3
Error E3 (undervoltage)
6.4
E4
Error E4 (fatal error)
6.4
Submenus
INF
INF menu
6.3.4
6.3.5
b01
Firmware version of LUB-V
h03
Currently set value of pause time h
c01
Currently set value of number of strokes c
PUL
Currently set operating mode: impulse mode
RUN
RUN menu
6.3.6
01...70
During the manually triggered active RUN command
("Quick check"/extra dispense), the LCD displays the
approximate back pressure in bar. In addition, the green
LED lights up.
PRO PRO menu
6.3.7
h1...99
Adjustable setting of pause time h
c1...10
Adjustbale setting of number of strokes c
PUL
Currently set operating mode: impulse mode
No changeable value