Model G0764 (Mfd. Since 02/14)
-39-
Test Run
Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning properly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The
Troubleshooting table in the
SERVICE section of this manual can help.
To test run machine:
1. Make sure you understand all safety instruc-
tions at the beginning of manual and that
machine is set up properly.
2. Make sure all tools and objects used during
setup are cleared away from machine.
3. Connect saw to power.
4. Push Emergency Stop button, then twist it
clockwise so it pops out. When button pops
out, switch is reset and will allow operation
(see
Figure 65).
Figure 65. Resetting Emergency Stop button.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
The test run consists of verifying the following:
1) The motors power up and run correctly, 2) the
safety features of the Emergency Stop buttons
work correctly, and 3) the main blade turns for-
ward (clockwise when viewed from front of saw)
and the scoring blade turns opposite main blade.
3. Connect ground wire, then connect incoming
power wires to bottom terminals shown in
Figure 64.
Figure 64. Terminal locations to connect
incoming power wires and ground wire.
Incoming Power
Terminals
4. Make sure wires have enough slack so they
are not pulled tight or stretched.
5. Re-install junction box cover, and perform
Test Run in following section to check phase
polarity.
Ground
Terminal
Make sure incoming ground wire is con-
nected to right-most terminal post in the
power junction box so machine is properly
grounded. An ungrounded or improperly
grounded machine may have an electrified
frame which could cause electrocution
when touched.