-38-
Model G0764 (Mfd. Since 02/14)
Before the machine can be connected to the
power source, an electrical circuit and connec-
tion device must be prepared per the
POWER
SUPPLY section in this manual; and all previous
setup instructions in this manual must be com-
plete to ensure that the machine has been assem-
bled and installed properly. The disconnect switch
installed by the electrician (as recommended) is
the primary means for disconnecting or connect-
ing the machine to the power source.
Power Connection
Figure 61. Connecting power to machine.
Move the disconnect switch handle to the ON
position, as illustrated below. The machine is now
connected to the power source.
Figure 62. Disconnecting power from machine.
Move the disconnect switch handle to the OFF
position, as illustrated below. The machine is now
disconnected from the power source.
Note: Lock the switch in the OFF position to
restrict others from starting the machine.
Electrocution, fire, or
equipment damage may
occur if machine is not
correctly grounded and
connected to the power
supply.
Note About Phase Converters: Due to the start-
up load from this machine, we do not recommend
using a static phase converter to create 3-phase
power—as it can quickly decrease the life of elec-
trical components on this machine. If you must
use a phase converter, only use a rotary phase
converter. Only connect the manufactured leg or
"wild wire" to the S terminal (see location on
Page
84). The S terminal can handle power fluctuation
because it is wired directly to the motor.
To connect saw to power:
1. Remove power junction box cover (see
Figure 63).
Figure 63. Location of junction box.
Power Junction
Box
Strain Relief
2. Insert incoming power wires through strain
relief in bottom of power junction box.