TTFM 6.1 Transit Time Flow Meter
SEPARATION DISTANCE (Sensor Spacing Distance)
Separation distance is automatically calculated by the TTFM 6.1 based on parameters entered in the
Setup menu. Sens Space is parameter where this distance is given, and it is located in the Setup menu.
Document this value for the following transducer installation procedure.
1 CROSS INSTALLATION OVERVIEW – TMK-B1 Kit
To assist with the proper installation of the transducers in a 1 cross installation, we provide a kit with
every meter, which consists of the following:
Sanding block
Tape measure
Mylar sleeve
Duct tape
Level
Black Sharpie
Follow along with the 1 cross installation instructions on the following pages for a description of where
to use these tools.
1. Prep the pipe per instructions on page 28, and mind the installation location requirements on
page 30. Clean the location where the sensor is to be mounted on the opposite side of the pipe
after we’ve marked where it will be installed. The picture below shows a very clean ductile iron
pipe which did not require much cleaning.