Page 14
TTFM 6.1 Transit Time Flow Meter
SET UP
Press
or
to position curser at Setup, and
to enter. Use
or
to position
cursor before each menu item and
to enter. When settings are completed press
to store and
again to return to the Main Menu.
Sensor
Select
Choose SE16B.
Angle
Select angle which matches the transducer pair connected to the
TTFM. Options: 35, 37, 39, and 41.
Angle is determined by the part number on the SE16-B
transducer label. Guide:
Part Number on SE16-B Label
Corresponding Transducer Angle
SE16-B-35
35
SE16-B-37
37
SE16-B-39
39
SE16-B-41
41
Fluid
Select fluid type.
Vel@25C
When Fluid = Other, enter the fluid velocity at 25C from table or
other reference. Engineering units may be m/s or ft/s depending
on Units menu programming.
dV/C
When Fluid = Other, Enter fluid velocity adjustment factor over
change in temperature in units of m/s or ft/s per °C.
Temp Mode
Choose Fixed.
Temp
Enter fluid operating temperature in displayed engineering units.
Pipe
Select pipe material.
Pipe Vel
When Pipe = Other, enter pipe material speed of sound (consult
factory).
OD
Highlight the digits and then
or
to change the numbers and
decimal point. Pipe OD should be entered as the exact outside
diameter of the pipe where the sensor is mounted. Refer to the
Pipe Charts Appendix in this manual for outside diameter of
common pipe types and sizes.
Wall
Enter pipe wall thickness. Pipe wall thickness should be entered
as the exact wall thickness of the pipe where the sensor is
mounted. Refer to the Pipe Charts Appendix in
this manual for wall thicknesses of common pipe types and
sizes.
Lining
Select liner material.
--
-------
Setup------
r
SE16B
Senso
Angle
37
°
Fluid
Water
Temp Mode
Fixed
Temp
77.0 F
Pipe
PVC
OD
4.5000 in
Wall
0.2500 in
Lining
None
Crossings
2
Zero Tare
No
Sens Space
2.299in
Velocity
0.00 ft/s
Signal
Strength
100
%
Summary of Contents for TTFM 6.1
Page 2: ...Note This page has been left blank intentionally ...
Page 5: ...Page 5 TTFM 6 1 Transit Time Flow Meter 100 240 VAC Meter CONNECTIONS ...
Page 27: ...Page 27 TTFM 6 1 Transit Time Flow Meter TYPICAL SENSOR INSTALLATION ...
Page 53: ...Page 53 TTFM 6 1 Transit Time Flow Meter SENSOR MOUNTING COUPLING RECOMMENDATIONS ...