Page 31
TTFM 6.1 Transit Time Flow Meter
SEPARATION DISTANCE (Sensor Spacing Distance)
Separation distance is automatically calculated by the TTFM 6.1 based on parameters entered in the
Setup
menu. Sens Space is parameter where this distance is given, and it is located in the
Setup
menu. Document this value for the following transducer installation procedure.
2 OR 4 CROSS INSTALLATION OVERVIEW - TMK-B1 Kit
1. Prep the pipe per instructions on page 28, and mind the installation location requirements on
page 30. Clean the location where the sensor is to be mounted on the opposite side of the pipe
after we’ve marked where it will be installed. Picture below shows a very clean ductile iron pipe
which did not require much cleaning. The outside paint is very well bonded and did not need to
be removed:
2.
Install the stainless steel mounting brackets on the pipe. Position them at approximately the
correct separation distance. Exact measurement is not required at this time. Tip: Use a 5/16” nut
driver to tighten the hose clamps.
Procedure continued on the next page…