Sleep Mode 2 (Adaptive Cycle)
1. Cool or Dry Mode (Initial setpoint between 610 F. - 740 F.)
a) After 1 hour of operation the temperature setting will raise 20 F every hour
b) After 3 hours of operation the temperature setting will raise 60 F above initial setpoint and stay at this
setting
c) After 7 hours of operation, the setpoint will move to 40 F. above the initial setpoint and remain until the
sleep mode in canceled.
Cool or Dry Mode (Initial setpoint between 750 F. - 810 F.)
a) After 1 hour of operation the temperature setting will raise 20 F every hour
b) After 3 hours of operation the temperature setting will raise 40 F above initial setpoint and stay at this
setting
c) After 7 hours of operation, the setpoint will move to 20 F. above the initial setpoint and remain until the
sleep mode in canceled.
Cool or Dry Mode (Initial setpoint between 820 F. - 850 F.)
a) After 1 hour of operation the temperature setting will raise 20 F every hour
b) After 3 hours of operation the temperature setting will raise 240 F above initial setpoint and stay at this
setting
c) After 7 hours of operation, the setpoint will move back to the initial setpoint and remain until the
sleep mode in canceled.
Cool or Dry Mode (Initial setpoint above 850 F.)
a) The original setpoint will be maintained for 7 hours, then after 7 hours it will decrease by 10 F until the
sleep mode is canceled
2. Heat Mode (Initial setpoint 610 F.)
a) The unit will maintain this setpoint until Sleep Mode is canceled
Heat Mode (Initial setpoint between 620 F. - 680 F.)
a) After 1 hour of operation the temperature setting will decrease 20 F and maintain this setpoint until
Sleep Mode is canceled
Heat Mode (Initial setpoint between 690 F. - 810 F.)
a) After 1 hour of operation the temperature setting will decrease 20 F and maintain this setpoint until
Sleep Mode is canceled
Heat Mode (Initial setpoint between 820 F. - 860 F.)
a) After 1 hour of operation the temperature setting will decrease 20 F every hour
b) After 3 hours, the setpoint will be fixed at 60 F below the initial setpoint and remain at this setpoint until
Sleep Mode is canceled
System Operation 18,000/24,000 btuh Models, cont.
Other Controls
Product Introduction
Summary of Contents for TERRA09HP230V1A
Page 13: ...13 Product Introduction Operation Characteristic Curve ...
Page 14: ...14 Product Introduction Capacity Variation Ratio According to Temperature ...
Page 16: ...16 Noise Criteria Curve Tables Product Introduction ...
Page 54: ...54 Electrical Schematics ...
Page 135: ...135 Gree Electric Appliances Inc C 2014 Cat No DFS TERRA HP 2SM Version 2 0 ...