115
Disassembly of Indoor Unit
24,000 btuh
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Step 1.
Remove the indoor tube temperature sensor
Step 2.
Remove the screws holding the bonding
wire, then remove the wire
Step 3.
Remove the clamps holding the electrical
box cover to remove cover.
Step 4.
Remove all wiring terminals, remove all
screws holding the box, then remove the
sub-assembly.
7. Remove electrical box sub-assembly
Temperature sensor
Electrical box cover
Sub-assembly
Summary of Contents for TERRA09HP230V1A
Page 13: ...13 Product Introduction Operation Characteristic Curve ...
Page 14: ...14 Product Introduction Capacity Variation Ratio According to Temperature ...
Page 16: ...16 Noise Criteria Curve Tables Product Introduction ...
Page 54: ...54 Electrical Schematics ...