81
Error Code Diagnostics
E5 - E6 Error Codes
E5
E6
Overcurrent Protection
Status:
During cooling & dehumidifying, indoor unit
operates while other functions stop; During
heating operation, complete unit stops
1.
Supply voltage is unstable
2.
Supply voltage is too low
3.
Coils are dirty
4.
Improper refrigerant charge
Fault & Status
Possible Causes
1. Refer to troubleshooting procedure next page
Communication Failure
Status:
Cooling operation, compressor stops while
indoor fans runs. Heating operation, complete
unit stops