25
Sleep Mode 3 (Customized Cycle)
You will be required to enter 8 room setpoint values for 8 hours of runtime. The last room setpoint value will be main-
tained until Sleep Mode is canceled.
In Sleep Mode 3, press the “Turbo” button to enter setup mode. The remote controller will display “1:00” in the time lo-
cation. Use the “+” and “-” buttons to select the desired room setpoint for the 1st hour of runtime, then press the “Turbo”
button to save the data.
The remote controller will display “2:00”. Once again, use the “+” and “-” buttons to select the desired room setpoint for the
second hour of run time. Press the “Turbo” button to save the data.
Repeat this procedure for the remaining hours (total of 8). After all 8 settings have been saved, the remote controller will
automatically revert back to the standard time and temperature display.
At anytime, you may press the “ON/OFF”, “MODE”, “TIMER”, “SLEEP” or “TURBO” buttons to cancel the Sleep Mode 3
7)Indoor Fan Control
The indoor fan can be set to Ultra High, High, Med, Low and Auto with the remote controller.
In auto mode, the following speeds will be set:
Cooling Mode
a) T
indoor
ambient >= T
setpoint
+ 20 F
,
fan will run on high speed
b) T
setpoint
- 20 F < T
indoor
ambient < T
setpoint
+ 20 F
,
fan will run on medium speed
c) T
indoor
ambient <= T
setpoint
- 20 F
,
fan will run on low speed
System Operation 9,000/12,000 btuh Models, cont.
Other Controls
Product Introduction
T
preset
T
preset
-20 F
T
preset
+ 20 F
Fan Speed
High
Med.
Low
Off
T
amb.
Summary of Contents for TERRA09HP230V1A
Page 13: ...13 Product Introduction Operation Characteristic Curve ...
Page 14: ...14 Product Introduction Capacity Variation Ratio According to Temperature ...
Page 16: ...16 Noise Criteria Curve Tables Product Introduction ...
Page 54: ...54 Electrical Schematics ...
Page 135: ...135 Gree Electric Appliances Inc C 2014 Cat No DFS TERRA HP 2SM Version 2 0 ...