217
Airbags
Malfunction judgment
1. Malfunction record (trouble code storage)
After the ECU performs the diagnostic test cycle in order to verify a malfunction, the SRS-ECU will store the
relevant code, the initial detection time, the final detection time, and the number of times it occurred in the
EEPROM.
The SRS-ECU can store 16 codes at most.
2. SRS-ECU approved trouble codes
No.
Malfunction introduction
Type code
Trouble
code
Possible
removal
1
(Front passenger side preload seat belt), connected to the
power supply
03H
01H
Removable
2
(Driver side front row preload seat belt), connected to the
power supply
03H
02H
Removable
3
(Driver side airbag assembly), connected to the power
supply
03H
03H
Removable
4
(Front passenger side airbag assembly), connected to the
power supply
03H
04H
Removable
5
(Front passenger side seat preload seat belt), grounded
02H
01H
Removable
6
(Driver side front row preload seat belt), grounded
02H
02H
Removable
7
(Driver side airbag assembly), grounded
02H
03H
Removable
8
(Front passenger side airbag assembly), grounded
02H
04H
Removable
9
(Front passenger side preload seat belt), resistance too
high or open circuit
01H
01H
Removable
10
(Driver side front row preload seat belt), resistance too
high or open circuit
01H
02H
Removable
11
(Driver side airbag assembly), resistance too high or open
circuit
01H
03H
Removable
12
(Front passenger side airbag assembly), resistance too
high or open circuit
01H
04H
Removable
13
(Front passenger side preload seat belt), resistance too
low or short circuit
0CH
01H
Removable
14
(Driver side preload seat belt), resistance too low or short
circuit
0CH
02H
Removable
15
(Driver side airbag assembly), resistance too low or short
circuit
0CH
03H
Removable
16
(Front passenger side airbag assembly), resistance too
low or short circuit
0CH
04H
Removable
17
Power supply voltage is out of range (high voltage or low
voltage)
12H
42H
Removable
18
Power cord contact dysfunctional
11H
42H
Removable
19
Warning lamp fault - connected to the power supply or
bulb is short circuited
03H
40H
Removable
20
Warning lamp fault - grounded or open circuit in filament
02H
41H
Removable
21
Configuration error
06H
44H
Removable
22
Internal malfunction
0DH
>80H
Irremovable
Replace
airbag ECU
Trouble code transmission is completed the SRS-ECU outputs through the maintenance program's
serial data interface to the specified diagnostic instrument (X-431 diagnostic scanner).
3. Internal malfunction
The microcontroller can detect the following items not only when starting up detection, but also during the
diagnostic detection cycle.
(a) The ignition circuit triggers the transistor: The high-end transistor will be detected not only when starting up