M10 JEWEL Machine - Electronic Engraving Machine
. 48
First Contact
Electrical characteristics
Connections - control panel - Links
Vers 2.0 - 15/11/2011
Sound signal according to standard ISO 11201
Environment
Optional accessories
Engraving softwares characteristics
M10 Jewel
machine
Waiting for engraving
LAeq
dB (A)
< 60
Nominal engraving
LAeq
dB (A)
< 60
Nominal engraving peak
Lp Cpeak
dB (C)
< 81.3
M10 Jewel
machine
Operational temperature
min. +5°C ; + 41°F - max. +40°C ; +104 °F
Stockage temperature
min. -5°C ; + 23°F - max. +45°C ; +113 °F
Degree of relative moisture when in use
20 to 80 %
Power
supply
(V)
Max.
absorbed
current
(A)
Frequency
(Hz)
Absorbed
power
(W)
Type of protection
Air
(bar)
Insulation
-
Type of
service
Electromagnetic
compatibility
Machine
fuses
MEPB
fuses
Fuses of
the optional
rack
Emission
Immunity
M10
Jewel
machine
Input :
AC
100-240 V
0,4 - 0,2
50-60
25
---------
---------
---------
------
Classe 1
-
S1
Norme
EN 55022
Classe B
…………
Norms
EN 61000-3-2
EN 61000-3-3
Norm
EN 61000-6-2
(industrial
environment)
M10 Jewel
machine
Connection to the PC
USB
Control panel
Membrane with raised tactile points
Nomber of keys
9
Display
No
Power supply connection
Jack
PC engraving software
Engraving software
GravoStyle 7
Operating system
(for the engraving software)
Windows XP pack 3 / Windows Vista pack 2 / Windows 7 pack 1
Languages
Fre, Eng, Ger, Ita, Spa, ...
Firmware/OS
>1.57