![Gravely 991001-008 Service Manual Download Page 79](http://html1.mh-extra.com/html/gravely/991001-008/991001-008_service-manual_2258607079.webp)
13 - 79
Models 992013, 014, 015, 016, 301
Normally open switches, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Module cannot be tested.
Seat Switch
Off
Run
Start
Yellow
12.00 Vdc
12.00 Vdc
Green
Holding circuit for the time delay
Time Delay
Off
Run
Start
Orange
12.00 Vdc
Green
12.00 Vdc
12.00 Vdc
Summary of Contents for 991001-008
Page 38: ...12 38 Figure 23 LP Low Pressure HP High Pressure FFBW Fluid Both Ways ...
Page 40: ...12 40 Models 992013 014 015 016 PF2020 Figure 25 ...
Page 54: ...13 54 Promaster 100 Kohler Command 50 Deck with Lift Models 991006 ...
Page 59: ...13 59 Promaster 100 Kohler 16 18 HP ...
Page 63: ...13 63 Promaster 100 Briggs Stratton ...
Page 68: ...13 68 Model 992010 011 Briggs Stratton ...
Page 75: ...13 75 Model 992015 016 Kohler 20 HP ...