13 - 56
Promaster 100 Kohler Command - 50" Deck with Lift, Models 991005, 006
Pins 85-86 coil resistance is 87-100 ohms.
Pins 30-87A normally closed.
Contact resistance is 0.1-0.3 ohms when correct.
Normally open contacts. Manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Normally open contacts. Manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Normally open contacts. Manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Relay - Deck Lift
Off
Run
Start
Black (85)
To Ground
Purple
12.00 Vdc
12.00 Vdc
Red
12.00 Vdc
12.00 Vdc
Red
12.00 Vdc
12.00 Vdc
12.00 Vdc
Open
12.00 Vdc
PTO Switch
Off
Run
Start
Yellow/Red
12.00 Vdc
12.00 Vdc
Brown/Yellow
12.00 Vdc
12.00 Vdc
Purple
12.00 Vdc
12.00 Vdc
Purple/White (to clutch)
12 volt when activated
Right Neutral Switch
Off
Run
Start
Red/Yellow
12.00 Vdc
12.00 Vdc
Red/Violet
12.00 Vdc
12.00 Vdc
Left Neutral Switch
Off
Run
Start
Brown/Yellow
12.00 Vdc
12.00 Vdc
Red/Yellow
12.00 Vdc
12.00 Vdc
Summary of Contents for 991001-008
Page 38: ...12 38 Figure 23 LP Low Pressure HP High Pressure FFBW Fluid Both Ways ...
Page 40: ...12 40 Models 992013 014 015 016 PF2020 Figure 25 ...
Page 54: ...13 54 Promaster 100 Kohler Command 50 Deck with Lift Models 991006 ...
Page 59: ...13 59 Promaster 100 Kohler 16 18 HP ...
Page 63: ...13 63 Promaster 100 Briggs Stratton ...
Page 68: ...13 68 Model 992010 011 Briggs Stratton ...
Page 75: ...13 75 Model 992015 016 Kohler 20 HP ...