![Gravely 991001-008 Service Manual Download Page 64](http://html1.mh-extra.com/html/gravely/991001-008/991001-008_service-manual_2258607064.webp)
13 - 64
Promaster 100 - Briggs & Stratton
Normally open, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Normally open switches, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Normally open switches, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Ignition Switch
Off
Run
Start
Brown (S)
12.00 Vdc
Red (B)
12.00 Vdc
12.00 Vdc
12.00 Vdc
White (M)
Connected to ground
Yellow (L)
12.00 Vdc
12.00 Vdc
White/Red (G)
Engine Magneto
Oil PSI Light
Off
Run
Start
Orange
12.00 Vdc
12.00 Vdc
Green
12.00 Vdc
12.00 Vdc
Hourmeter
Off
Run
Start
Black
12.00 Vdc
12.00 Vdc
White
12.00 to ground
12.00 to ground
PTO Interlock Switch
Off
Run
Start
Brown
12.00 Vdc
12.00 Vdc
Brown/White
12.00 Vdc
12.00 Vdc
Right Interlock Switch
Off
Run
Start
Brown/White
12.00 Vdc
12.00 Vdc
Brown
12.00 Vdc
12.00 Vdc
Summary of Contents for 991001-008
Page 38: ...12 38 Figure 23 LP Low Pressure HP High Pressure FFBW Fluid Both Ways ...
Page 40: ...12 40 Models 992013 014 015 016 PF2020 Figure 25 ...
Page 54: ...13 54 Promaster 100 Kohler Command 50 Deck with Lift Models 991006 ...
Page 59: ...13 59 Promaster 100 Kohler 16 18 HP ...
Page 63: ...13 63 Promaster 100 Briggs Stratton ...
Page 68: ...13 68 Model 992010 011 Briggs Stratton ...
Page 75: ...13 75 Model 992015 016 Kohler 20 HP ...