![Gravely 991001-008 Service Manual Download Page 72](http://html1.mh-extra.com/html/gravely/991001-008/991001-008_service-manual_2258607072.webp)
13 - 72
Model 992010, 011 Kawasaki 18 HP, Briggs & Stratton
Normally open switches, manually activated.
Contact resistance is 0.1-0.3 ohms when correct.
Seat Switch
Off
Run
Start
Yellow
12.00 Vdc
12.00 Vdc
Green
Holding circuit for the time delay
Ignition Switch
Off
Run
Start
Brown (S)
12.00 Vdc
Black (I)
12.00 Vdc
12.00 Vdc
12.00 Vdc
Purple (B)
12.00 Vdc
12.00 Vdc
Blue (R)
12.00 Vdc
12.00 Vdc
Green (A)
12.00 Vdc
12.00 Vdc
Time Delay
Off
Run
Start
Orange
12.00 Vdc
Green
12.00 Vdc
12.00 Vdc
PTO Switch
Off
Run
Start
Orange
12.00 Vdc
12.00 Vdc
Light Blue
When selected to on position - 12. 00 Vdc
White (Clutch)
Connected to ground