FC9000-UM-251-9370 9-18
9 TROUBLESHOOTING
Error
code
Error Display
Verification item
Cause
Solution
E02003
Confirm the
application software
is supporting this
plotter.
When wrong delimiter
received or there is
no delimiter in the
command, this error
is shown.
Set the correct model
name.
Configure your software
application menu to
permit Graphtec plotter
control.
When the USB cable
is using, confirm too
long cable is not
used.
The wrong data is
receiving by noise on
the data cable.
Confirm it is using
good cable.
Use good cable.
When the RS-232C
interface is using,
confirm transport
setting.
The data was missing
while transport via
the interface.
Re-specify the software
application’s interface
conditions.
When the RS-
232C cable is using,
confirm the correct
wiring of cable is
using.
The wrong wiring of
RS-232C cable is
using.
Use the correct wiring of
RS-232C cable.
E02004
Confirm the
application software
is supporting this
plotter.
The numeric
parameter of an input
command exceeds its
permissible range.
Set the correct model
name.
Configure your software
application menu to
permit Graphtec plotter
control.
Confirm it is using
good cable.
When the USB cable
is using, confirm too
long cable is not
used.
The wrong data is
receiving by noise on
the data cable.
Use good cable.
When the RS-232C
interface is using,
confirm transport
setting.
The data was missing
while transport via
the interface.
Re-specify the software
application’s interface
conditions.
When the RS-
232C cable is using,
confirm the correct
wiring of cable is
using.
The wrong wiring of
RS-232C cable is
using.
Use the correct wiring of
RS-232C cable.