FC9000-UM-251-9370 8-21
8 Electrical Adjustment
(9) Press the ENTER key to display the following menu.
Use the UP or DOWN position key to change the force setting.
(10) The pen is lowered. Use the Correx Dial Tension gauges to measure the actual force as shown in the
picture below.
And measure the actual force when the bottom of blade holder leaves from the cutting mat. Don’t
measure the force that keep lifting the tool.
(11)
If the measured value is not within the specification range (10±2g), reduce or increase the D/A value to
be within the specification range (10±2g).
(12)
Press the ENTER key when the measured value is within the specification range (10±2g).
(13)
The 48g-pen force specified pen force adjustment menu appears.
The pen is lowered. Use the Correx Dial Tension gauges to measure the actual force.
(14)
Adjust the 48g-pen force. If the measured value is not within the specification range (48±4g), reduce or
increase the D/A value to be within the specification range (48±4g).
(15)
Press the ENTER key when the measured value is within the specification range (48±4g).
(16)
The 130g-pen force specified pen force adjustment menu appears.
The pen is lowered. Use the Correx Dial Tension gauges to measure the actual force.
(17)
Adjust the 130g-pen force. If the measured value is not within the specification range (130±10g), reduce
or increase the D/A value to be within the specification range (130±10g).
(18)
Press the ENTER key when the measured value is within the specification range (130±10g).
(19)
The 210g-pen force specified pen force adjustment menu appears.
The pen is lowered. Use the Correx Dial Tension gauges to measure the actual force.
(20)
Adjust the 210g-pen force. If the measured value is not within the specification range (210±10g), reduce
or increase the D/A value to be within the specification range (210±10g).
(21)
Press the ENTER key when the measured value is within the specification range (210±10g).
(22)
The 515g-pen force specified pen force adjustment menu appears.
The pen is lowered. Use the Correx Dial Tension gauges to measure the actual force.
(23)
Adjust the 515g-pen force. If the measured value is not within the specification range (515±15g), reduce
or increase the D/A value to be within the specification range (515±15g).