Page 91
Appendix D - Parameters List
Input/output
Level
Parameter
Function description
Display and input value
Remarks
Group
Code
Default
Min.
Max.
Unit
I
51 07
Terminal 7-8 : DHW tank temperature probe
0=disable
1=enable
0
0
1
-
I
51 11
Terminal 11-12: thermal store temperature probe
0=disable
1=enable
0
0
1
-
To be set to
the following
combinations
parameter 5111=0
→Parameter
4200=0 or 2
parameter 5111=1
→Parameter
4200=0 or1 or 2
I
51 19
Terminal 19-18 : DHW remote contact
0=disable (Remote controller only)
1=enable
1
0
1
-
I
51 20
Terminal 20-21 : ON/OFF remote contact (CH)
Alarm input
0=disable
1=ON/OFF remote contact
1
0
1
-
I
51 28
Terminal 28-29 : Night mode*
0=disable
1=enable
Refer to Section 8.6.
0
0
1
-
Parameter 5128
and Parameter
5130 are
synchronised in
same value
I
51 30
Terminal 30-31 : Low tariff*
0=disable
1=enable
Refer to Section 8.7.
0
0
1
-
I
51 46
Terminal 46 : DHW Electric heater or Backup heater
0=DHW Electric heater
1=Backup heater
0
0
1
-
I
51 48
Terminal 48
0=disable
1=additional water pump
0
0
1
-
I
51 50
Terminal 50-52 : DHW 3way valve
0=disable
1=enable
1
0
1
-
Terminal 52: Live
Terminal 50:
Neutral
Earth to be
connected to
chassis ground
(refer to Section
C.2)
* External timer required