Page 44
9.1
SYSTEM SETUP
The numbers in Figure 9-1 will be used for the system setup in this
section.
Door open
Figure 9-1:
Remote controller buttons
9.1.1
TURNING THE HEAT PUMP ON AND OFF
Press
ON/OFF
switch
j
for three seconds to turn the heat pump
on or off. The green LED of
ON/OFF
switch is lit when the system
is ON.
The heat pump will start in response to a demand for either heating
or DHW.
! NOTE !
The heat pump may take up to seven minutes after the
demand as the heat pump will run the circulating pump and
check the water temperature in the system before starting.
9.2
SETTING THE DAY AND TIME
1. Press the
Set
button
p
for three seconds.
2.
The day ‘Mon’ indicator will blink.
Select the day by pressing the
-
or
+
buttons
o
and press set
button
p
to save the setting.
The day display stops blinking.
9
Commissioning
3. When the day of the week is set,
12:00
blinks; set the current
time by pressing the
-
or
+
button.
When the
-
or
+
buttons
o
is pressed, the time changes in one
minute increments; when the
-
or
+
buttons
o
is pressed and
held, it changes in ten minute increments.
Press the
Set
button
p
to save the time setting. Then the
display reverts to normal operation.
The accuracy of the clock is ±30 second/month.
If there is a power cut, the day and time setting is maintained for
approximately 24 hours. If the power cut continues over 24 hours,
the day and time must be reset.
After installation and before setting the time or when the heat pump
is reset after a power cut (lasting over 24 hours), the ‘12:00’ and
‘Mon’ will blink, indicating that the time must be reset.