Section 1: Introduction
Page 7
1.5
IMPORTANT ADVICE
1. It is essential that the full layout of the system is understood
before the installation of any component is undertaken. If you
are in any doubt, please stop and seek advice from a qualified
heating engineer or from Grant UK. Please note that Grant
UK will not be able to offer specific advice about your system
unless we designed it. In this case, we will always refer you to
seek the advice of a qualified system designer.
2. The heat pump must be installed and commissioned in
accordance with these installation and servicing instructions.
Deviations of any kind will invalidate the guarantee and
may cause an unsafe situation to occur. Please seek advice
from Grant UK if any of these user, installation and servicing
instructions cannot be followed for whatever reason.
3. The heat pump contains high pressures and high temperatures
during normal working conditions. Care must be taken when
accessing the internal workings of the heat pump.
4. The heat pump contains an electrically driven fan which rotates
at high speed. Disconnect the heat pump from the electrical
supply before removing the top cover.
1.6
PRODUCT CONTENTS
The Aerona³ comes supplied on a single pallet. The following items
are included:
Table 1-1:
Product Contents
HPID6R32
HPID10R32 HPID13R32 HPID17R32
Aerona³ heat pump 6kW
1
Aerona³ heat pump 10kW
1
Aerona³ heat pump 13kW
1
Aerona³ heat pump 17kW
1
Condensate drain elbow
1
1
1
1
Anti-vibration shoes
4
¾ʺ BSP x 22 mm flexible
hose c/w washer
2
1ʺ BSP x 28 mm flexible
hose c/w washer
2
2
2
1ʺ nipple
2
2
1ʺ x 1¼ʺ reducing socket
2
2
22 mm isolating valve
2
28 mm isolating valve
2
2
2
Remote controller
1
1
1
1
Remote controller cable
(length: 8 metres)
1
1
1
1
DN20 - 42 Flow regulator
1
1
1
DN20 - 70 Flow regulator
1
Installation and servicing
instructions
1
1
1
1
User instructions
1
1
1
1
1.7
INSTALLATION ACCESSORIES
The following are available from Grant UK:
Table 1-2:
Installation accessories
Product code
Description
HPIDFOOT/KIT2
Anti-vibration mounts (2 x 600mm and fixing kit)
HPIDINSU/KIT
Through wall insulation kit (22 - 28mm flexible hoses)
HPIDSYSLLHKIT
Grant System Combined Volumiser/Low Loss Header
HPIDVOL30EXT
30 litre External Volumiser with 3kW backup
Immersion Heater
HPIDR32PACK1
Grant Aerona³ Installation Pack A
HPIDR32PACK2
Grant Aerona³ Installation Pack B
HPIDR32PACK3
Grant Aerona³ Installation Pack C
1.8
CONTROL PARAMETERS
All parameters are listed sequentially in Appendix D.