Section 2: Technical Data
Page 9
2.1
HEAT PUMP TECHNICAL DATA
Table 2-1:
Technical data
Unit
Model
HPID6R32
HPID10R32
HPID13R32
HPID17R32
Heating capacity (BS EN 14511 - air: 7°C / water: 35°C)
kW
6.92
11.1
13.6
18.0
COP (BS EN 14511 - air: 7°C / water: 35°C)
4.91
5.28
5.25
4.79
SCOP (average climate conditions) - 35°C
4.61
5.20
5.40
4.54
Heating capacity (BS EN 14511 - air: 7°C / water: 55°C)
kW
6.24
10.5
11.4
15.3
COP (BS EN 14511 - air: 7°C / water: 55°C)
3.04
3.12
3.23
3.15
SCOP - average climate conditions (BS EN 14825 - water: 55°C)
3.29
3.47
3.72
3.57
Power supply
~230V 1ph 50Hz
Effective power input (BS EN 14511 - air: 7°C / water: 35°C)
kW
1.41
2.10
2.59
3.77
Effective power input (BS EN 14511 - air: 7°C / water: 55°C)
kW
2.05
3.36
3.53
4.87
Mechanical protection
IPX4
Compressor
DC twin rotary - inverter driven
Pressure (maximum)
MPa
4.2
Refrigerant
R32
Mass of R32
kg
0.80
1.55
2.20
2.80
Circulating pump
m head
10
6
12
12
Rated air flow (BS EN 14511 - air: 7°C / water: 35°)
m³/h
2,082
2,664
4,464
4,464
Rated air flow (BS EN 14511 - air: 7°C / water: 55°)
m³/h
2,082
2,664
4,664
4,464
Power input of fan (BS EN 14511 - air: 7°C / water: 35°)
kW
-
-
-
-
Power input of fan (BS EN 14511 - air: 7°C / water: 55°)
kW
-
-
-
-
Power input of circulating pump (BS EN 14511 - air: 7°C / water: 35°)
kW
-
-
-
-
Power input of circulating pump (BS EN 14511 - air: 7°C / water: 55°)
kW
-
-
-
-
Flow rate (minimum)
litres/min
5
10
15
15
Rated flow rate (BS EN 14511 - air: 7°C / water: 35°)
litres/min
20.22
32.16
40.68
50.88
Rated flow rate (BS EN 14511 - air: 7°C / water: 55°)
litres/min
11.34
19.26
20.76
27.90
Outdoor temperature
°C
-20 to 43
Maximum inlet water temperature (not operating)
°C
70
Water pressure (system)
MPa (bar)
0.1 to 0.3 (1 to 3 bar)
Sound power level at 1 metre (external)
dB(A)
65.2
64
60.8
61.6
Sound pressure level at 1 metre (external) (Q=1)
dB(A)
54.2
53
49.8
50.6
Water connections
BSPF
¾˝
1˝
1¼˝
1¼˝
Weight (empty)
kg
51
70
99
118
Weight (full)
kg
52.8
71.8
101
120
Water content
litres
1.8
1.8
2.0
2.0
Heat pump casing volume
m³
0.167
0.247
0.468
0.468
ErP rating (low temperature: 35°C flow) - heating
A++ (A+++ from September 2019)
ErP rating (low temperature: 55°C flow) - heating
A++ (HPID13R32 will be A+++ from September 2019)
2
Technical Data
Summary of Contents for Aerona 3 HPID10R32
Page 5: ...Page 5 Page intentionally left blank ...
Page 97: ...Page 97 Notes Notes ...
Page 98: ...Notes Page 98 Notes ...
Page 99: ...Page 99 Notes Notes ...