Section 16: Product Fiche
Models:
Outdoor
Unit:
Aerona³ HPID17R32
Indoor
Unit:
None
Air-to-water
heat
pump
Yes
Brine-to-water
heat
pump
No
Low
temperature
heat
pump
No
Equipped with a supplementary heater
No
Heat Pump Combination Heater
Yes
Parameters shall be declared for
Medium-temperature applications
Parameters shall be declared for
Average Climate Conditions
Item
Symbol
Value
Unit
Item
Symbol Value
Unit
Rated Heat Output (*)
Prated
12.2
kW
Seasonal Space Heating Efficiency
ƞs
142
%
Declared capacity for heating for part load at Indoor
Temperature 20°C and Outdoor Temperature Tj
Declared co-efficient of performance or primary energy ratio for
part load at Indoor temperature 20°C and Outdoor Temperatur Tj
Tj = -7°C
Pdh
12.8
kW
Tj = -7°C
COPd
2.34
Degredation co-efficient (**)
Cdh
0.99
-
Tj = +2°C
Pdh
7.40
kW
Tj = +2°C
COPd
3.61
Degredation co-efficient (**)
Cdh
0.99
-
Tj = +7°C
Pdh
9.10
kW
Tj = +7°C
COPd
5.21
Degredation co-efficient (**)
Cdh
0.99
-
Tj = +12°C
Pdh
6.11
kW
Tj = +12°C
COPd
8.12
Degredation co-efficient (**)
Cdh
0.99
-
Tj = bivalent temperature
Pdh
10.65
kW
Tj = bivalent temperature
COPd
2.21
Tj = Operation Limit Temperature
Pdh
9.60
kW
Tj = Operation Limit Temperature
COPd
2.15
Tj = -15°C (if TOL < -20°C)
Pdh
-
kW
Tj = -15°C (if TOL < -20°C)
COPd
-
Bivalent Temperature
Tbiv
-9
°C
Operation Limit Temperature
TOL
-10
°C
Heating water Operating Limit Temperature
WTOL
60
°C
Power consumption in modes other than active mode
Supplementary Heater
Off Mode
P
OFF
0.10
kW
Rate heat ouput
P
sup
0.00
kW
Thermostat-off mode
P
TO
0.04
kW
Standby mode
P
SB
0.10
kW
Type of energy input
Crankcase heater mode
P
CK
0.00
kW
Other items
Capacity Control
Variable
Rated airflow, outdoors
-
4464
m³/h
Sound Power Level (indoors/outdoors)
L
WA
41/61
dBA
Annual energy consumption
Q
HE
6938
kWh
For heat pump combination heater
Water heating energy efficiency
ƞwh
99
%
Declared load profile
-
L
-
Reference Hot Water
ϴ’
WH
49.42
°C
Daily electricity consumption
Q
elec
4.86
kW/h
Annual electricity consumption
AEC
1033.86
kW/h
*
For heat pumps, space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for
heating Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating
sup (Tj).
**