Appendix D - ADM Event and Error Codes Overview
313875J
77
T9C6
Red Blanket
Ctrl
Shutdown
PCB over temperature
Alarm
Overheated
Temperature Control
Module
Turn conditioning zone off. Wait a few minutes. If the
condition does not clear or regenerates consistently,
replace heater module
T9C5
Blue Blanket
Ctrl
Shutdown
Alarm
T9C3
Red Inline
Ctrl
Shutdown
Alarm
T9C1
Blue Inline
Ctrl
Shutdown
Alarm
T9C2
Red Hose Ctrl
Shutdown
Alarm
T9C4
Blue Hose
Ctrl
Shutdown
Alarm
T9C7
Red Chiller
Ctrl
Shutdown
Alarm
T9C8
Blue Chiller
Ctrl
Shutdown
Alarm
V1H1
Motor Control
Undervoltage
The voltage to the MCM has
dropped to a level where
performance is greatly affected
Alarm
Tripped circuit breaker
Visually check circuit breaker for a tripped condition
Supply lines providing
low voltage
Check incoming voltage to ensure it is above the
minimum operating voltage
V4A6
Red Blanket
Overvoltage
High line voltage
Alarm
Incoming line voltage is
too high
Measure voltage across disconnect switch. Voltage
should measure between 190 and 264 Vac.
V4B5
Blue Blanket
Overvoltage
Alarm
V4A3
Red Inline
Overvoltage
Alarm
V4B1
Blue Inline
Overvoltage
Alarm
V4A2
Red Hose
Overvoltage
Alarm
V4B4
Blue Hose
Overvoltage
Alarm
V4A7
Red Chiller
Overvoltage
Alarm
V4B8
Blue Chiller
Overvoltage
Alarm
V4H0
Motor Control
Overvoltage
The voltage to the MCM has
reached an unsafe level and
has been shutdown in an
attempt to prevent damage
Alarm
Supply lines providing
high voltage
Check incoming voltage to ensure it is below the
maximum operating voltage
W0U0
USB Update
Failed
The ADM tried to upload a
system settings file but failed
Alarm
System Settings file is
corrupt
Replace the system settings file with a backup or new
file
System Settings file is
intended for another
system
Ensure that the first line in the settings.txt file contains
the text GMS. If not replace the file with the proper
system update file.
WBH1
Motor
Encoder Fault
An error has been detected on
the motor position sensor
Alarm
Failing sensors
If error persists the motor will need to be replaced
Loose connection
Ensure the d-sub connector to the motor is connected
and the wiring is intact
Error
Code
Error Name
Error Description
Error
Type
Cause
Solution