Setup
313875J
23
4. Fill pump wet cups 2/3 full with
IsoGuard Select fluid.
5. Back-off air regulators to their full
counterclockwise position and
close all shutoff valves.
6. Install Flow Meters
NOTE:
This system ships with the flow meters removed.
The illustrations below shows what the flow meters will
look like after they are installed.
a.
Place the flow meter in position as shown in the
illustration below. The flow direction arrow is
pointed up and the sensor is on the outlet side
(top, as shown) of the flow meter.
b.
Hand tighten flow meter fittings to allow proper
positioning of the entire assembly.
c.
Install the output plumbing hand-tight. The out-
let plumbing includes the pressure sensor and
pressure gauge.
d.
Align the flow meter assembly and fully tighten
all fittings.
ti17707a
B (Blue) Side
A (Red) Side
NOTICE
To prevent damage, be careful when handling the
pressure sensor and pressure gauge assembly
because the pressure sensor cable is attached.
B (Blue) Side
A (Red) Side
B (Blue) Side
A (Red) Side
Summary of Contents for VPM 12
Page 9: ...A Red and B Blue Components 313875J 9...
Page 50: ...Maintenance 50 313875J...