Technical Data
26
3A1973L
Technical Data
SaniForce 515
US
Metric
Maximum fluid working pressure
100 psi
0.7 MPa, 7 bar
Air pressure operating range*
20-100 psi
0.14-0.7 MPa, 1.4-7 bar
Maximum air consumption
28 scfm
0.8 m
3
/minute
Air consumption at 70 psi/13.5 gpm
18 scfm
0.5 m
3
/minute
Maximum free-flow delivery
16 gpm
61 l/min
Maximum recommended cycle rate for
continuous duty
182 cycles per minute
Maximum size pumpable solids
3/32 in.
2.4 mm
Maximum viscosity
10,000 cps
Environmental temperature range
40°–120°F
4°–49°C
Minimum fluid temperature
40°F
4°C
Maximum fluid operating temperature
(Do not exceed the lowest maximum depending on the diaphragm, ball, and seat used in your pump.)
PTFE
220°F
104.4°C
Santoprene®
180°F
(82.2°C)
EPDM
275°F
(135°C)
Stainless steel
250°F
(121.1°C)
Maximum suction lift
Dry
15 ft.
4.6 meters
Wet
25 ft.
7.6 meters
Maximum pump speed
Standard Diaphragms
400 cycles per minute
Overmolded Diaphragms
500 cycles per minute
Fluid flow per cycle*
Standard Diaphragms
0.04 gallons
0.14 liters
Overmolded Diaphragms
0.03 gallons
0.11 liters
Noise (dBa)
Maximum sound pressure
78 dBa @ 70 psi (0.48 MPa, 4.8 bar)
Inlet/Outlet Sizes
Air inlet size
1/4 in. npt(f)
Air exhaust port size
3/8 npt(f)
Fluid inlet size
1 in. sanitary flange or 25 mm DIN
Fluid outlet size
1 in. sanitary flange or 25 mm DIN
Summary of Contents for SaniForce 515
Page 3: ...Models 3A1973L 3...