Installation
6
3A1973L
Installation
General Information
•
The typical installation shown in F
IG
. 2, page 8, is
only a guide for selecting and installing system com-
ponents. Contact your Graco distributor for assis-
tance in planning a system to suit your needs.
•
Always use genuine Graco parts and accessories.
•
Reference numbers and letters in parentheses refer
to the callouts in the figures.
Tighten Clamps Before First Use
After you unpack the pump, and before you use it for the
first time, check all clamps and tighten as necessary.
Grounding
•
Pump
: Attach a ground wire (Y) to the grounding
strip (8) with the screw (9a), lockwasher (9b), and
nut (9c), as shown in F
IG
. 1, and per local code.
Connect the clamp end of the ground wire to a true
earth ground. Order Part No. 238909 Ground Wire
and Clamp.
•
Fluid hoses
: Use only grounded hoses with a maxi-
mum of 500 ft. (150 m) combined hose length to
ensure grounding continuity.
•
Air compressor
: Follow the manufacturer’s recom-
mendations.
•
All solvent pails used when flushing:
Follow the local
code. Use only metal pails, which are conductive.
Do not place the pail on a non-conductive surface,
such as paper or cardboard, which interrupts the
grounding continuity.
•
Fluid supply container:
Follow the local code.
The pump is heavy and may cause injury if dropped.
Lift the pump by grasping the outlet manifold securely.
If dropped, the pump may rupture. To avoid serious
injury from splashing fluid, follow the
Pressure Relief
Procedure
on page 11 before moving the pump.
To reduce the risk of serious injury due to burns, insu-
late the pump before pumping hot fluids.
The equipment must be grounded. Grounding reduces
the risk of static and electric shock by providing an
escape wire for the electrical current due to static build
up or in the event of a short circuit.
F
IG
. 1: Ground the pump
Y
ti17654a
9c
9b
9a
8