Shutdown and Care of the Pump
For overnight shutdown, follow the
Pressure Relief Pro-
cedure
Warning
on page 6. Always stop the pump at the
bottom of the stroke to prevent the fluid from drying on the
exposed displacement rod and damaging the throat
packings.
Always flush the pump before the fluid dries on the dis-
placement rod. Never leave water or water–based fluid in
the pump overnight. First, flush with water or a compat-
ible solvent, then with mineral spirits. Relieve the pres-
sure, but leave the mineral spirits in the pump to protect
the parts from corrosion.