Troubleshooting
30
3A2152B
Drive Faults
The drives have a diagnostic window that should have a “4” when everything is normal.
If a drive has a problem, a series of numbers flash in this window. Below is a list of error codes.
Error
Code
Fault Message
RSLogix (HIM)
Problem or Symptom
Potential Cause
Possible Resolution
General
Power (PWR) indicator
not ON
No ac power or auxiliary
logic power.
Verify ac control power is
applied to the Kinetix 2000
system.
Internal power supply
malfunction.
Call your Rockwell Automa-
tion sales representative to
return module for repair.
Motor jumps when first
enabled
Motor wiring error.
•
Check motor wiring.
• Run Hookup test in RSLogix
5000 software.
Incorrect motor chosen. Verify the proper motor is
selected.
Digital I/O not working
correctly
I/O power supply discon-
nected.
Verify connections and I/O
power source.
E00
BusUndervoltage
Fault
(Blown fuse)
A blown fuse was
detected on the inverter
PCB
Blown fuse.
Call your Rockwell Automa-
tion sales representative to
return module for repair.