Technical Data
108
3A2152B
Technical Data
*
Catalyst and inhibitor can be incremented individu-
ally in 0.1% increments.
Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.5 to 10 cc's per second.
Ratio Range:
* Catalyst . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0% - 1%
* Inhibitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0% - 6%
Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
92% - 100%
Pigment (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . .
0% - 6%
Shot Size Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50 to 180 cc's, depending on ratio
Cycle Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dispense into screw varies depending on shot size and
flow rate. Pump reload time is 5 seconds
Maximum Fluid Pressre. . . . . . . . . . . . . . . . . . . . . . . . .
1000 psi (7 MPa, 69 bar)
Wetted Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
303 stainless steel, 304 stainless steel, polytetrafluoro-
ethylene (PTFE), ultra high molecular weight polyeth-
ylene (UHMW-PE) and fluoropolymer elastomer
Feed System Requirements (Not Included) . . . . . . . . .
Pressure feed systems that can feed the pumps at a
minimum of 400 psi (2.8 MPa, 28 bar).
Base inlet: 1 inch female NPT.
Catalyst/Inhibitor/Pigment inlet: ¼ inch JIC-4 male, 37°
flare.
Press Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3/4 inch NPT male thread to screw, inlet valve on screw
required. Maintained 24 vdc signal from press to activate
shot.
Sound Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
74.5 dB(A)
Weight, Valve Stack . . . . . . . . . . . . . . . . . . . . . . . . . . .
35 pounds (15.8 Kg)
Weight, Base Pump and Electrical Panel . . . . . . . . . . .
400 pounds (182 Kg)
Service Requirements:
Electrical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
208-240 volts, 3 phase, 3 wire with ground, 50-60 hertz,
30 amps full load
Pneumatic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Less than 1 scfm at 80-100 psi, ¼ inch female NPT inlet
Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50-60°F (10-15°C) chilled water for mixer jacket at
approximately ½ gpm (1.9 lpm), ¼ inch female NPT inlet
and outlet
Agency Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Approved to UL508a Standard
Summary of Contents for LSR Select
Page 7: ...Important Two Component Material Information 3A2152B 7...
Page 50: ...Parts 50 3A2152B Base Pump Wet Section 24L880 ti18115a 201 202...
Page 60: ...Parts 60 3A2152B Valve Stack 24L893 ti18160a 704 706 708 703 702 701 705 707 709 712 711 710...
Page 83: ...Control Schematics 24L890 3A2152B 83...
Page 93: ...Appendix A HMI Screens Overview 3A2152B 93...
Page 111: ...Accessories 3A2152B 111...