Appendix A - HMI Screens Overview
96
3A2152B
Ratio Check Setup Screen:
This screen is used to set up shot a flow rate values for
each component to do a single shot for troubleshooting.
1. BASE/INHIBITOR/CATALYST/COLOR SHOT
RANGE: This is used to set how far the pump will
travel to dispense a shot. The value is entered in
cc's and must be between the high and low limits of
travel noted under “Shot Range”
2. BASE/INHIBITOR/CATALYST/COLOR DISP.
SPEED RANGE: This is used to set how fast the
pump will move to dispense a shot. The value is
entered in cc's per second.
3. BASE/INHIBITOR/CATALYST/COLOR RELOAD
SPEED RANGE: This is used to set how fast the
pump will move to reload a shot. The value is
entered in inches per second.
NOTE:
This value is also used to reload the pump in
auto mode.
4. Setup Home push button: This is used to access the
screen to define the home position for a pump if the
pump loses its home position information.