Appendix A - Modbus Variable Map
1
—
—
Reserved
2
—
—
Reserved
3
Deviation
CAD_
CAN Communication Error Pump
4
Deviation
E5D_
Encoder Calibration Failed
5
Deviation
E5N_
Stroke Calibration Failed
6
Advisory
ENDC
Encoder/Stroke Range Calibration In Progress
7
Alarm
CCC_
Pump Could Not Find Display During Startup
8
Deviation
ELI_
Unexpected Hot Board Reset
9
Alarm
A5N_
Over Current
10
Advisory
ELD_
Reserved
11
—
—
Reserved
12
—
—
Reserved
13
—
—
Reserved
14
—
—
Reserved
15
—
—
Reserved
404117
404117
404117 --- Pump
Pump
Pump Events
Events
Events 2
2
2 —
—
— Low
Low
Low Word
Word
Word
Bit
Event Type
Event Code
Event Name
0
Advisory
E5F_
X2 Calibration Error, Too Fast
1
Advisory
ENN_
X2 Calibration Completed
2
Alarm
WNN_
Single Lower System with Display in Dual Lower Mode
3
—
—
Reserved
4
Advisory
E5S_
Dual Lower System Calibration Stopped or Interrupted
5
Advisory
E5U_
Dual Lower System Calibration Unsteady
6
Alarm
V9M_
Lower Supply Voltage Detected at Startup
7
—
—
Reserved
8
—
—
Reserved
9
—
—
Reserved
10
—
—
Reserved
11
—
—
Reserved
12
—
—
Reserved
13
—
—
Reserved
14
—
—
Reserved
15
—
—
Reserved
68
3A3453H